System Start-Up

1.
Place the unit in the bypass position. There is a pointer on the bypass valve handle.
This pointer should be pointing to "bypass" on the valve. When the bypass valve is in
the bypass position, the handle will bisect the plumbing connections.
2.
Turn on the main water supply.
3.
Open a cold soft water tap nearby and let water run a few minutes or until the system
is free of foreign material (usually solder) resulting from the installation. Close the
water tap when the water runs clean.
4.
Slowly place the bypass in the service position and let water flow into the mineral
tank. Open the bypass in small increments until it is fully open. When water flow
stops, slowly open a cold water tap nearby and let water run until air is purged from
the unit. Then close the tap once the water runs clear and there is no air in the
system.