Section 2: General Information Specifications - Generac Power Systems PWRcelP XVT076A03 Installation And Owner's Manual

Table of Contents

Advertisement

Section 2: General Information
Specifications
Description
Max. cont. grid-tied AC power @ 122°F (50ºC)
Max. cont. AC power in island mode w/ external transfer switch and
single 6 module battery cabinet
Max. cont. AC power in island mode w/ external transfer switch and 2 battery cabinets (8 mod-
1
ules minimum)
Peak motor starting current (2 sec)
Normal output frequency AC
Grid Voltage Line to Neutral (L-N)
Grid Voltage Line to Line (L-L)
Peak efficiency
Optimal split phase imbalance for max. system performance
CEC weighted efficiency
AC terminals wire size
DC terminals wire size
STOP terminals wire size
Normal Operating Performance Category
Abnormal Operating Performance Category
Weight
Thermal management
Weatherization rating
Enclosure Material
Description
REbus voltage
REbus current
REbus input short circuit current
Max input circuit backfeed current (fault condition)
Output power factor rating AC (25%, 50%, 100% of rated power)
Operating voltage range AC, XVT076A03 / (L-N)
Operating voltage range AC, XVT076A03 / (L-L)
Continuous output current AC grid-tied
Output controlled current AC grid-tied
Continuous output current AC islanded
Synchronization Inrush Current
Output fault current duration
Protected Loads output overcurrent protection
Full Power operating ambient temperature range
Trip voltage and frequency limits
Measurement and Calculation Accuracy
1
Peak performance, values provided for 104º F (40º C)
2
Rating for one DC input. Four total.
3
Includes ambient temperature rising from inverter operation.
4
Minimum voltage before disconnection is subject to UL 1741-SB low voltage ride-through and regional configurations requirements. Per require-
ments, the inverter shall perform required low voltage ride-through operation for one second. If required as specified by an Electric Utility, the
inverter may continue in operation past one second so long as the line-to-line voltage is greater than 40 Vrms
Inverter limits its REbus current to adhere to its AC power rating. Total REbus current capability from multiple REbus sources may safely
exceed this value as the inverter safely limits the amount utilized.
Installation and Owner's Manual for Generac PWRcell Inverter
2
2
3
Units
Min
V dc
360
A dc
A dc
A dc
-
0.96
V rms
106
4
V rms
212
A rms
A rms
0
A rms
A rms/p-p
A / ms
A
°F (°C)
-4 (-20)
See
Voltage and Frequency Trip Settings
See
General Information
Units
XVT076A03
kW
7.6
kW
9.0
kW
11.0
A rms
50
Hz
60
VAC
120
VAC
240
%
97.3
%
≤ 30
%
96.5
AWG
8 to 6
AWG
10 to 6
AWG
20 to 14
-
Category B
-
Category III
lb (kg)
70.9 (32.1)
forced convection
NEMA Type 3R
powder-coated steel
Nominal
Max
380
420
30
30
0
0.98
0.99
120
132
240
264
32
32
45
32.1 / 94.83
50 / 2,000
50
+122 (+50)
Table
2-1.
5

Advertisement

Table of Contents
loading