Activating The System Post Permission To Operate (Pto); Activating Post Pto: System Operating; Activating Post Pto: System Disabled - Generac Power Systems PWRcelP XVT076A03 Installation And Owner's Manual

Table of Contents

Advertisement

System Operation
Activating the System Post
Permission to Operate (PTO)
After a PWRcell system has been installed, it will need to
be inspected and granted permission to operate (PTO). A
PWRcell system may be left in one of two states while it
awaits PTO:
1. System Operating: making power with 'Export
Override' turned 'on' to restrict the system from
exporting to the utility grid.
2. System Disabled: not making power with inverter
and all components in a disabled state (inverter
screen may still be illuminated).
NOTE: For systems with a battery and a protected loads
panel, the inverter's grid connection should be closed
with its 2-pole 40 A over current protection device in the
ON position and the Protected Loads Disconnect in the
inverter in the ON position. This will allow the protected
loads panel to remain powered should the system be dis-
abled awaiting PTO.

Activating Post PTO: System Operating

1. From the home page on the inverter control panel,
use the right arrow key to navigate to the inverter
device page.
2. Press the center button to access the inverter
device main menu.
3. See
Figure
7-3. Use the down arrow key to scroll
to "Mod. Settings."
4. Select "Mod. Settings" using the center button.
5. See
Figure
7-4. Use the down arrow key to scroll
to 'Export Override' and select using the center but-
ton.
6. Use the up/down arrow keys to change the value of
'Export Override' from 'on' to 'off.'
7. Use the center button to deselect 'Export Override.'
8. Scroll to the bottom of the "Mod. Settings" menu
and select 'Save' to save the changes.
PWRcell 2P Inv.
Disable
Mod. Settings
Calibrate CTs
RCPn: 000100073212
< EXIT
SCROLL > NEXT • SELECT
Figure 7-3. Device Main Menu
50
ExtTransVolt
ExportOverride
CalOverride
CTTurnsRatio

Activating Post PTO: System Disabled

1. Ensure the inverter is powered ON with the screen
illuminated.
a. If the inverter is powered OFF, close the 2-pole
2. Lift the inverter lid and confirm the occupied DC
Disconnects on the left-hand side of the inverter
are in the ON position.
3. For systems with battery backup, ensure the Pro-
tected Loads Disconnect is in the ON position.
4. With the screen illuminated, from the home page
on the inverter control panel, press the center but-
ton to access the system modes menu.
5. See
arrow keys to scroll to the desired system mode
and select using the center button. See
Inverter System Mode
System Modes Overview
ity.
System Mode
Safety Shutdown
Grid Tie *
Menu
Self Supply
Clean Backup
< EXIT
Figure 7-5. Selecting System Modes (1 of 2)
013445
Installation and Owner's Manual for Generac PWRCell Inverter
Cancel
Figure 7-4. Mod Settings Menu
40 A over current protection device for the
inverter's AC grid connection by turning the
breaker or disconnect to the ON position.
and
Figure 7-5
Figure
for further instructions. See
SCROLL > NEXT • SELECT
off
Save
013446
7-6. Use the up/down
Select
for details on functional-
Menu