16.7
Stop selection
Select the stopping method (deceleration stop or coasting) at turn-OFF of the start signal.
Coasting can be selected for the cases such that the motor is stopped with a mechanical brake at turn-OFF of the start signal.
The operation of the start signal (STF/STR) can be selected. (For the start signal operation selection, refer to
Pr.
Name
250
Stop selection
G106
*1
For the start signal operation selection, refer to
*2
The start signal operation selection is available in External operation mode or when the start command source is External in the Network operation
mode.
 To decelerate the motor to a stop
• Set Pr.250 = "9999 (initial value) or 8888".
• The motor is decelerated to a stop when the start signal (STF/STR) is turned OFF.
 To coast the motor to a stop
• Set the time required to shut off the output after the start signal is turned OFF in Pr.250. When "1000 to 1100" is set, output
is shut off after a lapse of the (Pr.250 - 1000) seconds.
• The output is shut off after a lapse of the setting time of Pr.250 when the start signal is turned OFF. Motor coasts to a stop.
• The RUN signal is turned OFF when the output is shut off.
Initial
Setting range
value
STF signal: Forward rotation start
0 to 100 s
STR signal: Reverse rotation start
1000 to 1100
STF signal: Start signal
*2
STR signal: Forward/reverse rotation signal
9999
s
STF signal: Forward rotation start
9999
STR signal: Reverse rotation start
STF signal: Start signal
*2
8888
STR signal: Forward/reverse rotation signal
page
420.
Start
ON
signal
RUN
ON
signal
Start signal
ON
RUN signal
ON
Description
*1
Start signal (STF/STR)
Deceleration starts
when start signal turns OFF
Deceleration time
(Time set in Pr. 8, etc.)
DC injection brake
Time
OFF
OFF
Output is shut off when
set time elapses after
start signal turns OFF
Pr.250
Motor coasts to stop
Time
OFF
OFF
page
420.)
Stop operation
The motor coasts to a stop after a
lapse of the setting time when the
start signal is turned OFF.
The motor coasts to a stop after a
lapse of the (Pr.250 - 1000)
seconds when the start signal is
turned OFF.
The motor is decelerated to a stop
when the start signal is turned OFF.
16. (G) Control Parameters
16.7 Stop selection
11
12
13
14
15
16
17
18
19
20