 Input terminal function assignment
• Signals can be input to the inverter by using physical terminals (except for the FR-E800-SCE) or via communication, or
assigned to the extension terminals of the plug-in option (FR-E8AXY). Option input terminals are not available for the IP67
model as plug-in options are not available.
• Use parameters to assign functions to input terminals. Check the terminal available for each parameter.
Terminal
Pr.
name
FR-E800
178
STF/DI0
○ (STF)
179
STR/DI1
○ (STR)
180
RL
181
RM
182
RH
183
MRS
184
RES
185
NET X1
186
NET X2
187
NET X3
188
NET X4
189
NET X5
525
X1
526
X2
527
X3
528
X4
529
X5
530
X6
531
X7
○: Assignment/input available, ─: Assignment/input unavailable (no function)
*1
The communication protocol affects which terminals can be used. For details, refer to the Instruction Manual (Communication) or the Instruction
Manual of each communication option.
*2
Refer to the Instruction Manual of the option for details on the option input terminals.
NOTE
• For the available signals, refer to
External input terminal (physical terminal)
FR-E800-E
FR-E800-SCE
○ (DI0)
○ (DI1)
page
410.
Input via
communication
FR-E806
Forward rotation
○ (DI0)
command only
Reverse rotation
○ (DI1)
command only
2.8 I/O terminal function assignment
Option input terminal
*2
(physical terminal)
*1
FR-E8AXY
2. Basic Operation
1
2
3
4
5
6
7
8
9
10
51