 Monitor item list (Pr.52, Pr.774 to Pr.776, Pr.992)
• Use Pr.52, Pr.774 to Pr.776, or Pr.992 to select the monitor item to be displayed on the operation panel or the parameter
unit.
• Refer to the following table to find the setting value for each monitoring. The value in the Pr. setting column is set in each
of the parameters for monitoring (Pr.52, Pr.774 to Pr.776, and Pr.992) to determine the monitored item. The value in the
Communication column is the monitor code for communication. (The items marked with "—" cannot be selected. The circle
(○) in the Negative indication (-) column denotes that the monitored item can be indicated with minus sign during monitoring
via terminal AM, through communication, and to the FR-A8AY or FR-E8AXY. (Refer to
Increment
Monitor item
and unit
Output frequency
0.01 Hz
*18
(speed)
*8*9*18
0.01 A
Output current
*8*18
0.1 V
Output voltage
Fault indication
Set frequency / motor
0.01 Hz
*22
speed setting
Operation speed
1 r/min
Motor torque
0.1%
Converter output
0.1 V
*8
voltage
Regenerative brake
0.1%
duty
Electronic thermal O/L
0.1%
relay load factor
Output current peak
0.01 A
*8
value
Converter output
0.1 V
*8
voltage peak value
Input power
0.01 kW
*9
0.01 kW
Output power
Load meter
0.1%
Motor excitation
0.01 A
*8
current
*8*11
Position pulse
Cumulative
1 h
*5*22
energization time
*11
1
Orientation status
Actual operation
1 h
*5*6
time
Communication
Pr.
Monitor
Monitor
setting
*1
code 1
code 2
*17
1/0/100 H01
40201
2/0/100 H02
40202
3/0/100 H03
40203
0/100
*17
*4
H05
40205
5
*17
*4
H06
40206
6
*4
H07
40207
7
*4
H08
40208
8
*4
H09
40209
9
*4
H0A
40210
10
*4
H0B
40211
11
*4
H0C
40212
12
*4
H0D
40213
13
*4
H0E
40214
14
17
H11
40217
18
H12
40218
19
H13
40219
20
H14
40220
22
H16
40222
23
H17
40223
Negative
indication
*3
*2
(-)
The inverter output frequency is displayed.
The inverter output current effective value is displayed.
The inverter output voltage is displayed.
Each of the last 10 faults is displayed individually.
The set frequency is displayed. (0 Hz is displayed
during position control.)
The motor speed (number of rotations per minute) is
displayed.
The motor torque is displayed as a percentage (0%
under V/F control), considering the rated torque as
100%.
The DC bus voltage value is displayed.
The brake duty is displayed as a percentage,
considering Pr.70 setting value as 100%. (When Pr.30
= "0 or 100", Pr.70 is disabled.)
The motor thermal load factor or inverter thermal load
factor, whichever is larger, is displayed, considering the
thermal operation level as 100%.
The peak value of output current, which is constantly
stored, is displayed. (It is reset with every startup of the
inverter.)
The DC bus voltage peak value, which is constantly
stored, is displayed. (It is reset with every startup of the
inverter.)
The power at the inverter input side is displayed.
The power at the inverter output side is displayed.
Torque current is displayed as a percentage,
considering Pr.56 setting value as 100%. (0% is
displayed under the control mode other than V/F
control.)
The motor excitation current is displayed.
The number of pulses per motor rotation during
orientation control operation or in the position control
mode is displayed.
when a Vector control option is not installed.)
The cumulative energization time since the inverter
shipment is displayed. The number of times an
integrated value has reached the maximum value of
65535 hours can be checked in Pr.563.
Monitoring is enabled only during orientation control
operation. (The output voltage is displayed when a
Vector control option is not installed.) (Refer to
468.)
The cumulative operation time is displayed. The
number of times an integrated value has reached the
maximum value of 65535 hours can be checked in
Pr.564. Use Pr.171 to reset the cumulative operation
time. (Refer to
page
12. (M) Item and Output Signal for Monitoring
12.2 Monitor item selection on operation panel or via communication
page
357.))
Description
*20
(The output voltage is displayed
page
356.)
11
12
13
14
15
16
17
18
19
20
349