Mitsubishi Electric FR-E800 Instruction Manual page 352

Advertisement

Increment
Monitor item
and unit
Option input terminal
*11
status
Option output terminal
*11
status
Option input terminal
status 1 (for
*11
communication)
Option input terminal
status 2 (for
*11
communication)
Option output terminal
status (for
*11
communication)
Motor thermal load
0.1%
factor
Inverter thermal load
0.1%
factor
PTC thermistor
0.01 kΩ
resistance
Ideal speed command 0.01 Hz
PID measured value
0.1%
*22
2
Emergency drive
1
status
*8*11
Cumulative pulse
Cumulative pulse
*8*11
overflow times
32-bit cumulative
1 kWh
energy (lower 16 bits)
32-bit cumulative
1 kWh
energy (upper 16 bits)
32-bit cumulative
0.01 kWh
energy (lower 16 bits)
32-bit cumulative
0.01 kWh
energy (upper 16 bits)
BACnet reception
1
*22
status
BACnet token pass
1
*22
counter
BACnet valid APDU
1
*22
counter
BACnet
communication error
1
*22
counter
BACnet terminal FM
0.1%
*22
output level
Communication
Pr.
Monitor
Monitor
setting
*1
code 1
code 2
56
57
*14
H3A
40258
*15
H3B
40259
*16
H3C
40260
61
H3D
40261
62
H3E
40262
64
H40
40264
*17
65
H41
40265
67
H43
40267
68
H44
40268
71
H47
40271
72
H48
40272
H4D
40277
H4E
40278
H4F
40279
H50
40280
81
H51
40281
82
H52
40282
83
H53
40283
84
H54
40284
85
H55
40285
Negative
indication
*3
*2
(-)
The ON/OFF state of the digital input terminals on the
FR-A8AX or FR-E8AXY is displayed on the operation
panel. (Refer to
The ON/OFF state of the digital output terminals on the
FR-A8AY or FR-E8AXY or the relay output terminals on
the FR-A8AR is displayed on the operation panel.
(Refer to
page 354
The ON/OFF state of the digital input terminals X0 to
*14
X15 on the FR-A8AX is monitored via communication.
The ON/OFF state of the digital input terminal DY on the
*15
FR-A8AX or the digital input terminals X1 to X7 on the
FR-E8AXY is monitored via communication.
The ON/OFF state of the digital output terminals Y0 to
Y6 on the FR-A8AY, the digital output terminals Y1 and
*16
Y2 on the FR-E8AXY, or the relay output terminals RA1
to RA3 on the FR-A8AR is monitored via
communication.
The accumulated heat value of the motor thermal O/L
relay is displayed.
The Motor overload trip (electronic thermal relay
function) (E.THM) occurs at 100%.
The accumulated heat value of the inverter thermal O/L
relay is displayed.
The Inverter overload trip (electronic thermal relay
function) (E.THT) occurs at 100%.
The PTC thermistor resistance is displayed when
Pr.561 PTC thermistor protection level ≠ "9999".
(The output voltage is displayed when Pr.561 = "9999".)
The speed command ideal to create a position
command.
The PID measured value is displayed while the PID
control is enabled (Pr.128 ≠ "0"), even if PID control
operating conditions are not satisfied. (Refer to
488.)
Emergency drive status is displayed. (Available for the
FR-E800 and FR-E800-E.) (Refer to
The cumulative number of pulses (after multiplied by
*21
four) is displayed.
The number of the cumulative pulse overflow times is
*21
displayed.
The upper or lower 16 bits of the 32-bit cumulative
energy is displayed on each indication.
Monitoring via communication is available.
The BACnet reception status is displayed. (Available
only for the FR-E800.)
The count of received token is displayed. (Available
only for the FR-E800.)
The count of valid APDU detection is displayed.
(Available only for the FR-E800, FR-E800-(SC)EPA,
and FR-E806-SCEPA.)
The count of communication error detection is
displayed. (Available only for the FR-E800.)
The value set in the Analog Output object (ID = 0:
Terminal FM) for BACnet communication is displayed.
(Available only for the FR-E800-1.)
12. (M) Item and Output Signal for Monitoring
12.2 Monitor item selection on operation panel or via communication
Description
page 354
for details.)
for details.)
page
page
322.)
11
12
13
14
15
16
17
18
19
20
351