Download Print this page

Mitsubishi Electric FR-E800 Instruction Manual page 163

Advertisement

Speed limit
AU-OFF
Terminal 2
AU-ON
Terminal 4
[Pr.858 = 0]
Speed
setting
filter
RL
RM
RH
REX
Option
Operation
panel
Parameter
[Pr.808, Pr.809]
162
6. Torque Control
6.1 Torque control
Analog input offset
Terminal 2 bias [C2, C3(Pr.902)]
Terminal 2 gain [Pr.125, C4(Pr.903)]
Terminal 4 bias [C5, C6(Pr.904)]
Terminal 4 gain [Pr.126, C7(Pr.905)]
RT-OFF
[Pr.822 ≠ 9999]
[Pr.822]
[Pr.74]
[Pr.822 = 9999]
[Pr.832 ≠ 9999]
RT-ON
[Pr.832]
[Pr.74]
[Pr.832 = 9999]
Multi-speed
selection
[Pr.4 to Pr.6,
Pr.24 to Pr.27,
Pr.232 to Pr.239]
adjustment
[Pr.849]
Analog
input
selection
[Pr.73]
Operation Mode
Acceleration/deceleration
Maximum/minimum
setting
[Pr.1]
[Pr.2]
Speed limit selection
[Pr.79]
[Pr.807 = 0]
[Pr.807 = 1]
processing
A
[Pr.7]
[Pr.8]

Advertisement