 Monitoring the trace status
• The trace status can be monitored on the operation panel by setting "38" in Pr.52 Operation panel main monitor
selection, Pr.774 to Pr.776 (Operation panel monitor selection), or Pr.992 Operation panel setting dial push
monitor selection.
The content depends on the digits on the operation panel.
Monitor value
*1
No trace data in internal RAM
0 or no display
1
Trace data in internal RAM
2
*1
The value(s) "0" to the left of the leftmost non-zero value is(are) not shown in the monitor display. For example, if no trace data is in internal RAM,
sampling retry is not performed, no trigger is detected, and trace operation is performed, "1" appears (not "0001").
• During trace operation, the Trace status (Y40) signal can be output.
To use the Y40 signal, set "40" (positive logic) or "140" (negative logic) in any parameter from Pr.190 to Pr.197 (Output
terminal function selection) to assign function to an output terminal.
NOTE
• Changing the terminal assignment using Pr.190 to Pr.197 (Output terminal function selection) may affect the other
functions. Set parameters after confirming the function of each terminal.
Parameters referred to
Pr.52 Operation panel main monitor
Pr.178 to Pr.189 (Input terminal function
Pr.190 to Pr.197 (Output terminal function
1000s place
Indicates internal RAM state.
100s place
Indicates sampling retry state.
Fourth digit
Sampling retry not
performed
Sampling retry performed
Sampling retry count excess —
selectionpage 348
selection)page 392
selection)page 371
1s place
Indicates trace operation.
10s place
Indicates trigger state.
Trace status
Third digit
Second digit
Trigger not detected
Trigger detected
First digit
Tracing stopped
Trace operation
15. (A) Application Parameters
15.14 Trace function
11
12
13
14
15
16
17
18
19
20