Mitsubishi Electric FR-E800 Instruction Manual page 427

Advertisement

*2
The value is valid only when the FR-E820-0080(1.5K) or lower, the FR-E820S-0080(1.5K) or lower, or FR-E810W-0050(0.75K) or lower is used
and Pr.80 (Pr.453) ≤ 0.75 kW. Under other conditions, "SE" (Incorrect parameter setting) is displayed when the start command is turned ON.
*3
The value is valid in any of the following conditions. Under other conditions, "SE" (Incorrect parameter setting) is displayed when the start
command is turned ON.
The FR-E820-0470(11K) or lower is used and Pr.80 (Pr.453) ≤ 7.5 kW.
The FR-E840-0230(11K) or lower is used and Pr.80 (Pr.453) = 0.4 to 7.5 kW.
The FR-E820S-0110(2.2K) or lower is used and Pr.80 (Pr.453) ≤ 2.2 kW.
The FR-E810W-0050(0.75K) or lower is used and Pr.80 (Pr.453) ≤ 0.75 kW.
The FR-E846-0095(3.7K) or lower is used and Pr.80 (Pr.453) = 2.2 or 3.7 kW.
NOTE
• Regardless of the Pr.71 (Pr.450) setting, offline auto tuning can be performed according to Pr.96 (Pr.463) Auto tuning
setting/status. (Refer to
 Motor settings (575 V class)
• Refer to the following list and set the parameters according to the applied motor.
Pr.71
Pr.450
0 (Pr.71 initial value) Standard motor
10
30
8090
9090
3
13
33
8093
9093
5
15
6
16
9999
(initial
value)
NOTE
• Regardless of the Pr.71 (Pr.450) setting, offline auto tuning can be performed according to Pr.96 (Pr.463) Auto tuning
setting/status. (Refer to
426
14. (C) Motor Constant Parameters
14.1 Applied motor
page 430
for offline auto tuning.)
Motor
Constant-torque motor
Vector control dedicated motor
IPM motor
SPM motor
Standard motor
Constant-torque motor
Vector control dedicated motor
IPM motor
SPM motor
Standard motor
Constant-torque motor
Standard motor
Constant-torque motor
No second applied motor
page 430
for offline auto tuning.)
Motor constant value range when performing
offline auto tuning (increment)
Pr.82 (Pr.455), Pr.859 (Pr.860)
• 0 to 500 A, 9999 (0.01 A)
Pr.90 (Pr.458), Pr.91 (Pr.459)
• 0 to 50 Ω, 9999 (0.001 Ω)
Pr.92 (Pr.460), Pr.93 (Pr.461) (Induction motor)
• 0 to 6000 mH, 9999 (0.1 mH)
Pr.92 (Pr.460), Pr.93 (Pr.461) (PM motor)
• 0 to 650 mH, 9999 (0.01 mH)
Pr.94 (Pr.462)
• 0% to 100%, 9999 (0.1%)
Pr.706 (Pr.738)
• 0 to 5000 mV (rad/s), 9999 (0.1 mV/(rad/s))
Pr.82 (Pr.455), Pr.859 (Pr.860), Pr.90 (Pr.458),
Pr.91 (Pr.459), Pr.92 (Pr.460), Pr.93 (Pr.461),
Pr.94 (Pr.462), Pr.706 (Pr.738)
• Internal data value 0 to 65534, 9999 (1)
Pr.82 (Pr.455) and Pr.859 (Pr.860)
Wye
• 0 to 500 A, 9999 (0.01 A)
connection
Pr.90 (Pr.458), Pr.91 (Pr.459),
Pr.92 (Pr.460) and Pr.93 (Pr.461)
• 0 to 50 Ω, 9999 (0.001 Ω)
Delta
Pr.94 (Pr.462)
connection
• 0 to 500 Ω, 9999 (0.01 Ω)
Electronic thermal O/L
relay function
Constant-
Standard
torque