Pr.
Name
711
Motor Ld decay ratio
C131
712
Motor Lq decay ratio
C132
717
Starting resistance tuning
C182
compensation coefficient 1
Starting magnetic pole
721
position detection pulse
C185
width
725
Motor protection current
C133
level
1002
Lq tuning target current
C150
adjustment coefficient
979
Position accuracy
C194
compensation gain 1
980
Position accuracy
C195
compensation gain 2
981
Position accuracy
C196
compensation gain 3
450
Second applied motor
C200
453
Second motor capacity
C201
454
Number of second motor
C202
poles
51
Second electronic thermal
C203
O/L relay
456
Rated second motor
C204
voltage
457
Rated second motor
C205
frequency
743
Second motor maximum
C206
frequency
744
Second motor inertia
C207
(integer)
745
Second motor inertia
C208
(exponent)
463
Second motor auto tuning
C210
setting/status
458
Second motor constant
C220
(R1)
460
Second motor constant
C222
(L1) / d-axis inductance (Ld)
461
Second motor constant
C223
(L2) / q-axis inductance (Lq)
Second motor torque
860
current/Rated PM motor
C226
current
738
Second motor induced
C230
voltage constant (phi f)
442
14. (C) Motor Constant Parameters
14.3 Offline auto tuning for a PM motor
Initial
Setting range
value
9999
0% to 100%, 9999
9999
0% to 100%, 9999
9999
0% to 200%, 9999
9999
0 to 6000 μs, 9999
100% to 500%
9999
9999
50% to 150%
9999
9999
9999
90% to 110%, 9999
9999
90% to 110%, 9999
9999
90% to 110%, 9999
0, 3, 5, 6, 10, 13, 15, 16,
20, 23, 30, 33, 40, 43, 50,
*6
53, 70, 73, 540
, 1140
9999
1800, 1803, 8090, 8093,
*1
9090, 9093
9999
0.1 to 30 kW
9999
9999
2, 4, 6, 8, 10, 12
9999
9999
0 to 500 A
9999
9999
200/400/
0 to 1000 V
*3
575 V
10 to 400 Hz
9999
9999
0 to 400 Hz
9999
9999
9999
10 to 999, 9999
9999
0 to 7, 9999
0
*5
1
0
11
*4
9999
0 to 50 Ω, 9999
9999
0 to 500 mH, 9999
9999
0 to 500 mH, 9999
*4
9999
0 to 500 A, 9999
0 to 5000 mV (rad/s)
9999
9999
Tuning data (The value measured by offline auto tuning is
automatically set.)
9999: Inverter internal data is used.
Set the maximum current (OCT) level of the motor.
*8
230%
Adjust the target current during tuning.
100%
Tuning data
(The value measured by position accuracy compensation
gain tuning is automatically set.)
*9
9999: No function
Set this parameter when using the second motor
*7
,
(the same specifications as Pr.71).
The function is disabled.
Set the capacity of the second motor.
No second motor capacity setting
Set the number of poles of the second motor.
No number of second motor poles setting
Set the rated current of the second motor.
Second electronic thermal O/L relay disabled.
Set the rated voltage (V) of the second motor.
Set the rated frequency (Hz) of the second motor.
Inverter internal data is used.
Set the permissible speed (frequency) of the second motor.
The Pr.457 setting is used.
Set the motor inertia of the second motor.
9999: Inverter internal data is used.
No auto tuning for the second motor.
Offline auto tuning is performed without the second motor
rotating (when driving a motor other than the MM-GKR or
EM-A).
Offline auto tuning is performed without the second motor
rotating.
*4
Tuning data of the second motor.
(The value measured by offline auto tuning is automatically
set.)
*4
9999: Inverter internal data is used.
Set this parameter according to the PM motor
*4
specifications.
The value calculated from the parameter setting for motor
constant is used.
Description