Pareo Dcm 711 Control Module; Variants; Dimensions; Environmental Requirements - Xylem FLYGT Pareo DCM 711 Installation, Operation And Maintenance Manual

Control module
Table of Contents

Advertisement

9.2 Pareo DCM 711 control module

9.2.1 Variants

Bluetooth
8261400

9.2.2 Dimensions

1. 211.2 mm (8.3 in)
2. 223.6 mm (8.8 in)
3. 69.5 mm (2.7 in)

9.2.3 Environmental requirements

Parameter
Operating temperature
Maximum altitude
Voltage measurements
Overvoltage category
Pollution degree
Humidity
Installation location

9.2.4 Electrical data

Parameter
Supply voltage
Current range
Frequency
DCM 711 Installation, Operation, and Maintenance Manual
Part number
Bluetooth
WLAN
8261401
1
2
Voltage rating, V
200–1000
3
Value
-20°C to 40°C (-4°F to 104°F)
Maximum 2000 m (6562 ft)
1000 VAC
Category III
2
95%
Relative humidity, non-condensing
Indoors.
Outdoor use is possible if the product is installed in
a suitable cabinet.
Value
3~
200–1000 VAC
Tolerance: -10% to +10%
Up to 250 A
50/60 Hz
9 Technical Reference