3.6 Alarms

For more information about the LED behavior of the alarms, see
Priority level
Priority level
Class A
Class B
Alarm events
Event
Present
Triggered @
Acknowledged @

3.6.1 Alarm information

Alarm
Data plate
mismatch, pump
current
Data plate
mismatch, voltage
Motor
overtemperature
Overload, pump
current
Overvoltage
DCM 711 Installation, Operation, and Maintenance Manual
Possible cause
Remedy
The current from
Check that the
the electronic data
control box is
plate of the pump
configured to match
does not match the
the pump.
configured current
range of the
controller.
The voltage from
Check that the
the electronic data
control box is
plate of the pump
configured to match
does not match the
the pump.
configured voltage
range of the
controller.
The thermal
Check the pump
sensors detect that
temperature.
the temperature is
higher than the
permitted limit.
The pump current
Check the power
is higher than the
supply.
permitted limit. The
current overload
protection trips.
The voltage is
Check the power
higher than the
supply.
permitted limit.
User Interface
Description
• This alarm has the highest priority.
• A Class A alarm stops the pump. It is not
possible to start the pump until the alarm is
inactive.
• The alarm appears as a red indication on all the
user interfaces.
• A Class B alarm does not stop the pump. It is
possible to start the pump when the alarm is
active.
• The alarm appears as a yellow indication on all
the user interfaces.
Description
The alarm condition is present.
The date and time that the alarm is triggered
The date and time that the alarm is acknowledged
Priority level
Class A
Class A
Class A
Class A
Class A
3 Function Description
on page 33.
Reset
Manual
Manual
Manual
Manual
Automatic
15