5.3.4

Reboot/Switch off module

Reboot
Press and hold the push button (2) for 5-15 seconds. Release the button when the green LED is lit.
Switch Off
Press and hold the push button (2) for 15-20 seconds. Make sure to release the button when the red LED is lit. If re-
leasing the push button after more than 20 seconds, the module will not switch off.
6

Administration reference

6.1

Purpose

This chapter contains detailed information about configuring options and the different message formats of the LoRa
Module.
6.2

Security and access control

The LoRa Module has a "configuration lock" feature, which prevents unauthorized access to the module. When
"configuration lock" has been enabled, a Product Access Key will be needed to configure the device. For more in-
formation about security and access control, please refer to the One-touch commissioning (OTC) documentation,
available on the Elvaco website.
6.3

Configuration options

The LoRa Module is configured via the Elvaco OTC app. It uses NFC to transfer settings to the module. Downlink may
also be used to for some configurations, see section 6.3.1 Downlink for more information.
The LoRa Module can also be configured using the optical interface configuration tool "Device Monitor".
Please note that the Elvaco OTC App is compatible with Android phones with Android 5.0 or later.
Table 3 provides a summary of all LoRa Module parameters and settings.
Figure 4: Reboot/switch off module