Size
Large
9.1.3 Environmental requirements
Parameter
Operating temperature
Maximum altitude
Overvoltage category
Pollution degree
Installation location
9.1.4 Electrical data
Parameter
Supply voltage
Current range
Frequency
Bluetooth frequency band
Maximum radio frequency power transmitted
9.1.5 Glass fuse properties
Dimensions, diameter x length
5 x 20 mm (0.2 x 0.8 in)
DCM 711 Installation, Operation, and Maintenance Manual
Dimensions
1. 279.5 mm (11.0 in)
2. 440 mm (17.3 in)
3. 523 mm (20.6 in)
4. 209 mm (8.22 in)
Value
-20°C to 40°C (-4°F to 104°F)
Maximum 2000 m (6562 ft)
Category III
2
Outdoors
Value
IEC
• 3~
• 200–240 VAC, 380–690 VAC
• Tolerance: ± 10%
UL, CSA
• 3~
• 200–240 VAC, 380–600 VAC
• Tolerance: ± 10%
For more information, see
50/60 Hz, ± 10%
2.4 GHz – 2.5 GHz
+8.3 dBm
Rating
T315 mA, 250 VAC
9 Technical Reference
Variants
on page 44.
Type
Slow-blow, T
45