Error
Description
M-301
Memory
abnormal
M-302
Machine type
parameter error
M-303
UK parameter
abnormal
M-304
Main PCB
parameter
abnormal
M-305
Normal seam
pattern
parameter
abnormal
M-306
Error
Seam pattern
number
M-307
Seam pattern
data abnormal
M-308
Sewing data too
great
114
Possible cause
Control panel memory data
abnormal.
The machine type data read by
the control panel is outside of
the set range.
Abnormal range of the
parameter that was read from
the EEPROM by the control
panel.
Abnormal range of parameters
received from the control by the
control panel.
During the use of seam pattern
parameters, the control panel
detects an abnormal parameter
range.
The selected seam pattern is
not stored in ROM or has been
disabled. The seam pattern is
"0"
While the sewing data of the
seam pattern is read by the
control panel, the system
detects an abnormal data
format.
The volume of the seam pattern
data is found to be too great
during the calculation.
Operating Instructions 513/533 - 01.0 - 09/2023
Troubleshooting
Troubleshooting
• Internal error: The user needs
to update the software of the
control panel.
• Press the RESET button
to call up parameter 241
automatically and select and
save the corrected machine
type.
• Press the RESET button to
call up the system menu and
restore the default setting.
• Press the RESET button to
call up the system menu and
restore the default setting.
• Press the RESET button to
call up the system menu and
restore the default setting.
• Press the RESET button to
confirm the seam pattern
number.
• Select different seam
patterns.
• Select different seam patterns
for sewing.