3. To open the AC input area of the projector, remove the six screws seucring the cover and
swing the cover downwards to open it.
4. Taking the approved line cord for your location, strip the cable jacket to expose a 120 mm
length of the bundled wires.
5. Cut the Line (black or brown) and Neutral (white or blue) wires to shorten them to a length
between 80 to 100 mm.
6. Using a wire stripper, strip the insulation from each individual wire to expose 10 mm of bare
wire on the end.
7. Pass the wires through the strain relief on the knockout plate and through the AC input cover.
8. Fasten the bare end of the wires into the Ground (G), Line (L), and Neutral (N) terminal block
connectors, starting first with the Ground (green) connection, followed by the Line (black or
brown) and Neutral (white or blue) connections.
CP4415-RGB and CP4420-RGB Gen2 Installation and Setup Guide
020-103773-01 Rev. 1 (02-2023)
Copyright
©
2023 Christie Digital Systems USA, Inc. All rights reserved.
If printed, please recycle this document after use.
Installing and setting up