Dalsa Linea Lite GigE Series User Manual page 92

2k / 4k monochrome & color cmos line scan
Table of Contents

Advertisement

Example: CounterStartSource = Line (Edge Base) Example 2
Countermode = Active
Countermode = OFF
Counter is
IDLE
CounterDuration = 12
CounterStartSource =
Line 1
CounterTriggerActivation =
Falling Edge
Any Tick in
CounterEventSource
90 • Operational Reference
CounterStartSource = Line (Edge Base ) Example 2
Counter STATUS
Counter
Active
Trigger Wait
0
1
5
The Second StartSource Pulse is ignored
Figure 75: Example – CounterStartSource = Line (Edge Base)
CounterEnd Event Generated
Counter
Active
Active
Completed
8
12
0
CounterResetSource =
CounterEnd(Itself)
Active
Counter Register
1