Dalsa Linea Lite GigE Series User Manual page 75

2k / 4k monochrome & color cmos line scan
Table of Contents

Advertisement

User Set Selector
Factory Setting
UserSet 1
UserSet 2
UserSet 3
UserSet 4
Load Configuration
Save Configuration
Device ID
Calibration Date
Device Acquisition Type
Sensor
Device TL Type
GigE Vision
Device TL Version Major
Device TL Version Minor
Power-up Configuration
Selector
None
Factory Setting
UserSet1
to
UserSet4
DFNC Major Rev
DFNC Minor Rev
SFNC Major Rev
SFNC Minor Rev
SFNC SubMinor Rev
Linea Lite GigE Series Camera
UserSetSelector
UserSetLoad
UserSetSave
DeviceID
deviceCalibrationDateRaw
deviceAcquisitionType
DeviceTLType
DeviceTLVersionMajor
DeviceTLVersionMinor
UserSetDefaultSelector
deviceDFNCVersionMajor
deviceDFNCVersionMinor
DeviceSFNCVersionMajor
DeviceSFNCVersionMinor
DeviceSFNCVersionSubMinor
Selects the camera configuration set to load feature
settings from or save current feature settings to.
The Factory set contains default camera feature
settings. User camera configuration sets contain
features settings previously saved by the user.
(RW)
Default
Select the default camera feature settings saved by
the factory.
UserSet1
Select the User Defined Configuration space
UserSet 1 to save to or load from features settings
previously saved by the user.
UserSet2
Select the User Defined Configuration space
UserSet 2 to save to or load from features settings
previously saved by the user.
UserSet3
Select the User Defined Configuration space
UserSet 3 to save to or load from features settings
previously saved by the user.
Select the User Defined Configuration space
UserSet4
UserSet 4 to save to or load from features settings
previously saved by the user.
Loads the camera configuration set specified by the
User Set Selector feature, to the camera and m akes
it active. (W)
Saves the current camera configuration to the user
set specified by the User Set Selector feature. The
user sets are located on the camera in non-volatile
m emory. (W)
Displays the device's factory set serial number.
Date when the camera was calibrated.
Displays the Device Acquisition Type of the product.
(RO)
Sensor
The device gets its data directly from a sensor.
Transport Layer type of the device.
GigEVision
GigE Vision Transport Layer
Major version of the device's Transport Layer.
Minor version of the device's Transport Layer.
Selects the camera configuration set to load and
m ake active on camera power-up or reset. The
cam era configuration sets are stored in camera
non-volatile m emory. (RW)
None
Keep Internal configuration.
Select the Factory Setting values as the Power-up
Default
Configuration.
UserSet1
Select the user defined configuration as the Power-
to
up Configuration.
UserSet4
Major revision of Dalsa Feature Naming Convention
which was used to create the device's XML. (RO)
Minor revision of Dalsa Feature Naming Convention
which was used to create the device's XML. (RO)
Major Version of the Standard Features Naming
Convention which was used to create the device's
XML. (RO)
Minor Version of the Standard Features Naming
Convention which was used to create the device's
XML. (RO)
Subm inor Version of the Standard Features Naming
Convention which was used to create the device's
XML. (RO)
Operational Reference • 73
Beginner
Beginner
Beginner
Invisible
Invisible
DFNC
Invisible
DFNC
Invisible
Invisible
Invisible
Invisible
Invisible
DFNC
Invisible
DFNC
Invisible
Invisible
Invisible