Advertisement

Counter Start Source
Off
Acquisition Start
Acquisition End
Exposure Start
Exposure End
Rejected Trigger
Frame Start
Valid Frame Trigger
Line 1
Line 2
Line 3
Timer 1 End
Counter 1 End
Counter Start Line
Activation
Rising Edge
Falling Edge
Any Edge
Counter Incremental
Source
Off
Acquisition Start
Acquisition End
Exposure Start
Exposure End
Frame Start
Valid Frame Trigger
Rejected Trigger
Line 1
Line 2
Line 3
Internal Clock
Timer 1 End
Linea Lite GigE Series Camera
counterStartSource
AcquisitionStart
AcquisitionEnd
ExposureStart
ExposureEnd
InvalidTrigger
FrameStart
ValidFrameTrigger
Line1
Line2
Line3
Timer1End
Counter1End
counterStartLineActivation
RisingEdge
FallingEdge
AnyEdge
counterIncrementalSource
AcquisitionStart
AcquisitionEnd
ExposureStart
ExposureEnd
FrameStart
ValidFrameTrigger
InvalidTrigger
Line1
Line2
Line3
InternalClock
Timer1End
Select the counter start source. Counter increments from
0 to the value of the
Counter Duration
Off
Counter is stopped.
Counter starts on the reception of an Acquisition Start
event.
Counter starts on the reception of an Acquisition End
event.
Counter starts on the reception of an Exposure Start
event.
Counter starts on the reception of an Exposure End
event.
Counter starts on the reception of an Invalid Trigger
event.
Counter starts on the reception of a Frame Start event.
Counter starts on the reception of a Valid Frame Trigger
event.
Counter starts on the specified transitions on Line 1.
See Input Signals Electrical Specifications.
Counter starts on the specified transitions on Line 2.
Counter starts on the specified transitions on Line 3.
Counter starts on the reception of the Timer 1 End event.
Counter starts on the reception of the Counter 1 End
event.
Selects the activation mode of the input line trigger which
starts the counter. This is only applicable when the
counterStartSource feature selects a physical Line.
Starts counting on rising edge of the selected Line.
Starts counting on falling edge of the selected Line.
Starts counting on the falling or rising edge of the
selected Line.
Select the event source which increments the counter.
The
Event Control section
diagram s for the supported events.
Off
Counter is stopped.
Counts the number of Acquisition Start events.
Counts the number of Acquisition End events.
Counts the number of Exposure Start events.
Counts the number of Exposure End events.
Counts the number of Frame Start events.
Counts the number of Valid Frame Trigger events.
Counts the number of Invalid Trigger events.
Counts the number of transitions on Line 1 (based on the
counterIncrementalLineActivation feature setting).
See Input Signals Electrical Specifications.
Counts the number of transitions on Line 2 (based on the
counterIncrementalLineActivation feature setting).
Counts the number of transitions on Line 3 (based on the
counterIncrementalLineActivation feature setting).
The counter increments on each microsecond tick of the
device internal Clock.
Counts the number of Timer 1 End events.
feature.
provides details and timing