Dalsa Linea Lite GigE Series User Manual page 83

2k / 4k monochrome & color cmos line scan
Table of Contents

Advertisement

Line Selector
Line 1
Line 2
Line 3
Line 4
Line 5
Line Format
RS422
Open Collector
Line Mode
Input
Output
Line Status
Line Inverter
Input Line Detection Level
Threshold for TTL
Input Line Debouncing
Period (in μs)
Line Electrical Termination
Disabled
Enabled
Linea Lite GigE Series Camera
LineSelector
Line1
Line2
Line3
Line4
Line5
LineFormat
RS422
OpenCollector
LineMode
Input
Output
LineStatus
False / True
LineInverter
False / True
lineDetectionLevel
Threshold_for_TTL
lineDebouncingPeriod
lineElectricalTermination
Disabled
Enabled
Selects the physical line (or pin) of the external device
connector to configure.
Index of the physical line and associated I/O control block
to use. Pin 1 and Pin 2 is the RS-422 Input Port 1+, 1-,
respectively.
Index of the physical line and associated I/O control block
to use. Pin 3 and Pin 4 is the RS-422 Input Port 2+ and 2-
, respectively.
Index of the physical line and associated I/O control block
to use. Pin 6 and Pin 7 is the Port 3+ and 3-, respectively.
Index of the physical line and associated I/O control block
to use. Pin 11 and Pin 12 is Output Port 4+ and 4-,
respectively.
Index of the physical line and associated I/O control block
to use. Pin 13 and Pin 14 is the Output Port 5+ and 5-,
respectively.
Specify the current electrical format of the selected
physical input or output. Applies to all physical lines. (RO)
The line accepts or sends RS422 level signals.
The line is an output line configured as an open collector.
Reports if the physical Line is an Input or Output signal.
(RO)
See Input Signals Electrical Specifications.
See Output Signals Electrical Specifications.
The line is an input line.
The line is an output line.
Returns the current status of the selected input or output
line. (RO)
Controls whether to invert the polarity of the selected
input or output line signal.
Specifies the voltage threshold required to recognize a
signal transition on an input line.
A signal below 0.8V will be detected as a Logical LOW and
a signal greater than 2.4V will be detected as a Logical
HIGH on the selected input line.
Specifies the minimum delay before an input line voltage
transition is recognized as a signal transition.
Controls if the electrical termination of both Line 1 and 2 is
enabled or disabled.
Line termination is disabled.
Line termination is enabled.
Operational Reference • 81
Beginner
Expert
Expert
Expert
Beginner
Expert
DFNC
Beginner
DFNC
Expert
DFNC