Dalsa Linea Lite GigE Series User Manual page 153

2k / 4k monochrome & color cmos line scan
Table of Contents

Advertisement

External Output Details
The output signals can be used in programmable output mode such as strobe, event
notification, etc. (See
For the Single-Ended Open Collector outputs, the user supplied pull-up resistor value should
be between 1 kΩ and 10 kΩ depending on supply rail. Resistor Wattage should be calculated
accordingly.
Outputs are open (disabled) on power-up with the default factory settings.
A software reset will not reset the outputs to the open state if the outputs are active.
A user setup configured to load on boot will not reset the outputs to the open state if the
outputs are active.
The output signals are designed to prevent an output signal glitch on power-up or polarity
reversal.
Protection Circuit – DC Ratings:
Output protected against shorts to ground or other voltages
Output maximum voltage of 26 V at 10 mA (at 60°C)
Linea Lite GigE Series Camera
Output Line Source
feature).
Technical Specifications • 151