Dalsa Linea Lite GigE Series User Manual page 90

2k / 4k monochrome & color cmos line scan
Table of Contents

Advertisement

Example: Counter Start Source = OFF
Countermode = OFF
Counter is
IDLE
CounterStartSource = OFF
The counter starts on the counterReset Cmd.
The counter continues unless a new counterReset Cmd is received, which then restarts the
counter at 00.
When Counter Reset Source= 'Event' or 'CounterEnd' the counter is reset to 00 but does
not restart counting, until the next CounterReset Cmd.
Example: Counter Start Source = CounterEnd (itself)
Countermode = OFF
Counter is
IDLE
CounterStartSource =
CounterEnd (itself)
Counter starts when Counter Mode is set to Active.
A Counter Reset CMD will reset the counter to 00 and it then continues counting.
88 • Operational Reference
CounterStartSource = OFF
Countermode = Active
Counter
Trigger Wait
Counter is incrementing
0
Figure 71: Example – Counter Start Source = OFF
CounterStartSource = CounterEnd (itself)
Countermode = Active
Counter
Trigger Wait
Counter is incrementing
0
Figure 72: Example – Counter Start Source = CounterEnd
CounterEnd Event Generated
Counter is
Counter
Active
Completed
CounterEnd Event Generated
Counter is
Counter
Active
Completed
Counter
Overflow
CounterResetSource = OFF
Counter Reset CMD
CounterResetSource = Event
CounterResetSource = CounterEnd
Counter Reset CMD
CounterResetSource = CounterEnd
Linea Lite GigE Series Camera

Advertisement

Table of Contents
loading

Table of Contents