Dalsa Linea Lite GigE Series User Manual page 118

2k / 4k monochrome & color cmos line scan
Table of Contents

Advertisement

PTP Port Last Event
None
Power up
Initialize
Designated Enabled
Designated Disabled
Fault Cleared
Fault Detected
State Decision Event
Qualification Timeout
Expires
Announce Receipt
Timeout Expires
Synchronization Fault
Master Clock Selected
Recommended State
Master
Recommended State
Grand Master
Recommended State
Slave
Recommended State
Passive
PTP Transport Protocol
PTP Servo Step Threshold
(in us)
Threshold_10
Threshold_20
Threshold_100
Threshold_500
Threshold_1000
Threshold_2000
Tim estamp Modulo Event
Tim estamp Modulo Event
Frequency
Tim estamp Modulo Start
Tim e
Tim estamp Modulo Actual
Start Tim e
Gev Tim estamp Latch
Gev Tim estamp Value
Gev Tim estamp Tick
Frequency
Gev Tim estamp Reset
116 • Operational Reference
ptpPortLastEvent
None
Powerup
Initialize
DesignatedEnabled
DesignatedDisabled
FaultCleared
FaultDetected
StateDecisionEvent
QualificationTimeoutExpires
AnnounceReceiptTimeoutExpires
SynchronizationFault
MasterClockSelected
RS_Master
RS_GrandMaster
RS_Slave
RS_Passive
ptpTransportProtocol
ptpServoStepThreshold
Threshold_10
Threshold_20
Threshold_100
Threshold_500
Threshold_1000
Threshold_2000
tim estampModulo
tim estampModuloFrequency
tim estampModuloStartTime
tim estampModuloActualStartTime
Gevtim estampControlLatch
Gevtim estampValue
Gevtim estampTickFrequency
Gevtim estampControlReset
Logs the last PTP changed state event defining the last
current status.
None
Power up
Initialize
Designated Enabled
Designated Disabled
Fault Cleared
Fault Detected
State Decision Event
Qualification Timeout Expires
Announce Receipt Timeout Expires
Synchronization Fault
Master Clock Selected
Recommended State Master
Recommended State Grand Master
Recommended State Slave
Recommended State Passive
Describes the PTP Transport Protocol used.
Specifies the servo step threshold (in μs). When the clock
offset with the master exceeds the threshold, the servo
unlocks and offset adjustment is started.
10 μs threshold.
20 μs threshold.
100 μs threshold.
500 μs threshold.
1000 μs threshold.
2000 μs threshold.
Specifies the additional interval between the current
tim estamp tick and the event generated. This interval has
an 80ns accuracy. Note that the value zero disables the
event generator.
Returns the frequency of the timestamp m odulo event (in
Hz).
Specifies the timestamp value that must be exceeded by
the incrementing timestamp counter before the m odulo
event starts. This feature is also used for a "future" frame
acquisition.
Displays the actual m odulo event start time as used by the
device. When the user specified
Tim e
is in the future, Tim estamp Modulo Actual Start Tim e
= Tim estamp Modulo Start Tim e. When the user-specified
Tim estamp Modulo Start Tim e
automatically recalculates a future value for
Modulo Start Tim e
using the user set
Event
feature value. This new start time is reported by
Tim estamp Modulo Actual Start Tim e.
Latch the current timestamp internal counter value in the
Gev Tim estamp Value feature. (WO)
Returns the 64-bit value of the timestamp counter. (RO)
Indicates the number of timestamp ticks (or increments)
during 1 second (frequency in Hz). (RO)
Resets the timestamp counter to 0. (WO)
Timestamp Modulo Start
has already past, the camera
Tim estamp
Timestamp Modulo
Linea Lite GigE Series Camera
Expert
DFNC
Expert
DFNC
Expert
DFNC
Expert
DFNC
Expert
DFNC
Expert
DFNC
Expert
DFNC
Invisible
Invisible
Invisible
Invisible

Advertisement

Table of Contents
loading

Table of Contents