Dalsa Linea Lite GigE Series User Manual page 45

2k / 4k monochrome & color cmos line scan
Table of Contents

Advertisement

Example of Free Run Line Mode with Frame Trigger
An example setup of free run line acquisition with Frame Trigger and a configurable internal timer
is used as follows:
Set
AcquisitionLineRate
Set image
Height
Select
Trigger Selector
Set
Trigger Mode
Select
Trigger Source
Setup Timer1:
Set
Timer Start Source
Timer Duration
Timer Mode
Then click the CamExpert Grab button.
Example of Line Trigger Mode
An example setup of a Line Trigger acquisition using internal timer with a configurable internal
timer is as follows:
Set image
Height
Select
Trigger Selector
Set
Trigger Mode
Select
Trigger Source
Setup Timestamp Modulo Event:
Use Timestamp Latch Cmd to start the timestamp using the camera's internal clock
timeStampModulo= 10000 (frame rate = 100 Hz)
Then click the CamExpert Grab button.
Linea Lite GigE Series Camera
= 20000 Hz
= 100
= SingleFrameTrigger (Start)
= On
= Timer1EndEvent
= Timer1End
= 5000
set = Active
= 100
= SingleLineTrigger(Start)
= On
= Timestamp Modulo Event
Camera Performance and Features • 43

Advertisement

Table of Contents
loading

Table of Contents