Q5X Laser Triangulation Sensor With Dual Mode And IO-Link For Jam Detection Instruction Manual
This setting is automatically applied during any subsequent teach operation. The window size value represents a ±cm value,
so the total window size is twice this value. For example, a window set of 10 cm gives a 20 cm window centered around the
taught point. The window size can also be changed directly from Run mode after changing the setting to any value except
Auto. For Channel 2, the output must be set to light operate or dark operate.
Values: 0.1 cm to 191 cm
Background Suppression (bGS1 and bGS2)
Use this menu to manually set the background suppression point for the jam background suppression mode. This menu is
available only if jam background suppression mode is selected. This point can also be set via the TEACH procedure.
Measurements beyond this set point are qualified as not jammed.
Response Speed (SPd)
Use this menu to select the response speed.
Default: 50 milliseconds
Tradeoffs
Response Speed
15 ms
25 ms
50 ms
Output Timing Delays (dLY1 and dLY2)
Use this menu to select the output timing delay to be set.
On and off delay timers can be used together. The default is no delay.
•
—No delay
•
—Delay—enables the selection of on and off delay timers
•
—One-shot—enables a one-shot, fixed output pulse duration
When one of the timing delay options is chosen, the sensor returns to the Setup menu and additional options become
available to set the parameter(s):
•
—On delay
•
—Off delay
20
Response Speed in Sync Mode
30 ms
50 ms
100 ms
Output
OFF Delay
D
ON Delay
D
1-Shot
Repeatability
Ambient Light Rejection
3 ms
Enabled
5 ms
Enabled
10 ms
Enabled
Output Timing Delays
D
D
D
Time
© Banner Engineering Corp.
Excess Gain
See Excess Gain in "Specifications"
on page
41
ON
OFF
D
(D = 1ms - 90.0s)
July 10, 2023