2.1.5 Wiring the Fault Alarm Contact

The fault alarm contacts are in the middle (3 & 4) of the terminal block connector as the picture shows below. Inserting the wires,
the Industrial Managed PoE+ Switch will detect the fault status of the power failure, or port link failure (available for managed
model). The following illustration shows an application example for wiring the fault alarm contacts
1. The wire gauge for the terminal block should be in the range of 12 ~ 24 AWG.
2. When performing any of the procedures like inserting the wires or tightening the wire-clamp screws,
make sure the power is OFF to prevent from getting an electric shock.

2.1.6 Wiring the Digital Input/Output

The 6-contact terminal block connector on the rear panel of Industrial Managed PoE+ Switch is used for Digital Input and Digital
Output. Please follow the steps below to insert wire.
1.
The Industrial Managed PoE+ Switch offers two DI and DO groups. 1 and 2 are DI groups, 3 and 4 are DO groups, and 5
and 6 are GND (ground).
Insert the wires into the fault alarm contacts
DI DO
Figure 2-4: Wiring the DI and DO of Industrial Managed PoE+ Switch.
User's Manual of IGS-10020HPT-U