Wiring The Fault Alarm Contact; Product Features - Planet IFGS-1022HPT User Manual

Industrial 8-port 10/100tx 802.3at poe+ plus 2-port gigabit tp/sfp combo ethernet switch
Hide thumbs Also See for IFGS-1022HPT:
Table of Contents

Advertisement

2.6 Wiring the Fault Alarm Contact

The fault alarm contacts are in the middle of the terminal block connector as
the picture shows below. Inserting the wires, the Industrial PoE+ Switch will
detect the fault status of the power failure and then forms an open circuit. The
following illustration shows an application example for wiring the fault alarm
contacts.
Fault Alarm Contacts
1. The wire gauge for the terminal block should be in the range
between 12 and 24 AWG.
2. Alarm relay circuit accepts up to 24V with a maximum current
of 1A.

2.7 Product Features

 Physical Port
z Eight 10/100BASE-TX Fast Ethernet RJ45 ports with IEEE 802.3at/af PoE+
injector function (Port 1 to Port 8)
z Two 10/100/1000BASE-T Gigabit Ethernet RJ45 ports (Port 9 and Port 10)
z Two 1000BASE-X mini-GBIC/SFP slots for SFP type auto detection (Port 9
and Port 10)
 Power over Ethernet
z Complies with IEEE 802.3at Power over Ethernet Plus, end-span PSE
10
Fault
Alarm
Insert the wires into the fault alarm contacts
The Fault Alarm Contacts are
energized (CLOSE) for normal
operation and will OPEN when
failure occurs

Advertisement

Table of Contents
loading

Table of Contents