4.3.16.5 Event Settings

This page allows the user to inspect the current Link OAM Link Event configurations, and change them as well, as screen in
Figure 4-3-16-5
appears.
The page includes the following fields:
General Settings
Object
• Port
• Event Name
• Error Window
• Error Threshold
• Error Frame Event
• Symbol Period Error
Event
Figure 4-3-16-5: Event Settings Page Screenshot
Description
The switch port number.
Name of the Link Event which is being configured.
Represents the window period in the order of 1 sec for the observation of various
link events.
Represents the threshold value for the window period for the appropriate Link
event so as to notify the peer of this error.
The Errored Frame Event counts the number of errored frames detected during
the specified period. The period is specified by a time interval ( Window in order
of 1 sec). This event is generated if the errored frame count is equal to or greater
than the specified threshold for that period (Period Threshold). Errored frames
are frames that had transmission errors as detected at the Media Access Control
sublayer. Error Window for 'Error Frame Event' must be an integer value between
1-60 and its default value is '1'. Whereas Error Threshold must be between
0-4294967295 and its default value is '1'.
ved in a time interval on the underlying physical layer. This event is generated if
the symbol error count is equal to or greater than the specified threshold for that
period. Error Window for 'Symbol Period Error Event' must be an integer value
between 1-60 and its default value is '1'. Whereas Error Threshold must be
between 0-4294967295 and its default value is '1'.