Stroke Sensor "Sigma - ProMinent S1Ba 12017 PVT Operating Instructions Manual

Diaphragm motor-driven metering pump
Table of Contents

Advertisement

Technical data
a) Contact (standard with identity code
specification "Displacement mechanism":
A)
a) Namur sensor (for identity code specifi‐
cation "Displacement mechanism": A)

15.11 Stroke sensor "Sigma"

a) Pacing relay (stroke sensor with ...)
(Identity code specification "Stroke
sensor": 2)
64
Tab. 6: Contact loading, max.
with voltage
Maximum current
30 V DC
1 A
The diaphragm rupture sensor is an N/C.
For safety reasons we recommend connection to protective low
n
voltage, e.g. in accordance with EN 60335-1 (SELV).
The cable can be connected as required.
n
Install the sensor in accordance with the chapter "Installation, electrical".
Refer to its documentation.
Sensor name: NJ1.5-8GM-N.
5–25 V DC, in accordance with Namur or DIN 60947-5-6, potential-free
design.
Data
Nominal voltage *
Power consumption - active surface
uncovered
Power consumption - active surface cov‐
ered
Rated switching distance
* Ri ~ 1 kΩ
Cable colour
Polarity
blue
-
brown
+
Install the sensor in accordance with the chapter "Installation, electrical".
For more information, see "Pacing relay" in the "Relay" chapter.
Value Unit
8 V DC
> 3 mA
< 1 mA
1.5 mm

Advertisement