13.7

Stroke sensor "Sigma"

a) Pacing relay (stroke sensor with ...)
(Identity code specification "Stroke
sensor": 2)
b) Namur sensor (identity code specifica‐
tion "Stroke sensor": 3)
13.8

Relay

Motor data sheets, special motors, special motor flanges,
external fan, temperature monitoring
Motor data sheets can be requested for more informa‐
tion.
For motors other than those with identity code specifica‐
tions "S", "M" or "N": Pay special attention to the oper‐
ating instructions for the motors.
Special motors or special motor flanges are possible on
request.
Install the sensor according to the chapter "Installation, elec‐
trical".
For more information, see "Pacing relay" in the "Relay" chapter.
5–25 V DC, in accordance with Namur or DIN 60947-5-6, potential-free
design.
Data
Nominal voltage *
Power consumption - active surface
uncovered
Power consumption - active surface cov‐
ered
Rated switching distance
* Ri ~ 1 kΩ
Cable colour
Polarity
blue
-
brown
+
The electrical data for the relay are contained in the chapter
"Installation, electrical".
Technical data
Value Unit
8 VDC
> 3 mA
< 1 mA
1.5 mm