13.10 Safety relief valve (HP2 and HP3)

13.11 Stroke sensor

Namur sensor (identity code characteristic
"stroke sensor": 1)
Namur sensor (Specified for EX zones)

13.12 Heating cartridge

86
Opening pressure of the respective pressure stages:
Pressure
6 bar
10
stage*
bar
Opening pres‐
10
14
sure**
bar
bar
* Marking on the indicating scale without valve housing
** back pressure generated by the pump when discharge side is blocked ±
3 bar
Install the sensor in accordance with the chapter "Instal‐
lation, electrical".
5–25 V DC, in accordance with Namur or DIN 19234, potential-free
design.
Data
Rated voltage *
Power consumption - active surface
uncovered
Power consumption - active surface cov‐
ered
Rated switching distance
* Ri ~ 1 kΩ
Cable colour
Polarity
blue
-
brown
+
Install the sensor in accordance with the chapter "Instal‐
lation, electrical". Refer to its documentation.
The sensor is of type NJ1.5-8GM-N.
Technical data - see enclosed operating instructions
16
25
40
64
bar
bar
bar
bar
25
36
49
80
bar
bar
bar
bar
Value Unit
8 VDC
> 3 mA
< 1 mA
1.5 mm
100
bar
120
bar