Base; Space Requirement - ProMinent S1Ba 12017 PVT Operating Instructions Manual

Diaphragm motor-driven metering pump
Table of Contents

Advertisement

Model size
63
Dimensions in mm - unless otherwise indicated.
* Motor is fitted directly onto the motor flange without intermediate flange and claw coupling.

6.2 Base

h
Fig. 11: Base

6.3 Space requirement

A
A
Fig. 12: Space requirement
f
1
f
f
3
Fig. 13: Clearance (f)
Liquid end alignment
Motor flange
B 5/140 *
The pump can break through the base or slide off it
Ensure that the base is horizontal, flat and permanently load-bearing.
n
Dosing rate too low
Vibrations can disturb the valves of the liquid end.
n
Do not allow the base to vibrate.
n
P_MOZ_0016_SW
WARNING!
Motor may overheat
If the necessary cooling air supply is not guaranteed, the
motor may overheat. In an area at risk from explosion, it
could trigger an explosion.
P_MOZ_0018_SW
CAUTION!
Danger from incorrectly operated or inadequately main‐
tained pumps
Danger can arise from a poorly accessible pump due to
incorrect operation and poor maintenance.
Position the pump so that control elements, such as the stroke length
adjustment knob or the indicating dial A, are easily accessible.
1
Discharge valve
2
Dosing head
2
3
Suction valve
Ensure there is sufficient clearance (f) around the dosing head as well as
the suction and discharge valve so that maintenance and repair work can
be carried out on these components.
P_MOZ_0017_SW
Dosing rate too low
The valves of the liquid end cannot close correctly if the valves of the
n
liquid end are not upright.
Ensure that the discharge valve is upright.
n
Q
(26)
Maintain sufficient clearance between the air intake
opening and the walls. The distance should be
greater than 1/4 of the diameter of the air intake
opening.
The fan must not suck in the exhaust air from other
devices.
Ensure that the pump is accessible at all times.
Adhere to the maintenance intervals.
Assembly
29