Stroke Sensor - ProMinent Hydro/4 Operating Instructions Manual

Metering pump
Table of Contents

Advertisement

ATEX pressure switch

13.12 Stroke sensor

Namur sensor (identity code specification
"Stroke sensor": 1)
Namur sensor (Specified for EX zones)
For safety reasons we recommend connecting to a pro‐
tective low voltage, e.g. in accordance with EN 60335-1
(SELV ).
The cable can be connected as required.
CAUTION!
Observe the accompanying manual "HYDAC Operating
manual pressure switch series EDS 4400 with ATEX
approval".
Type identification
Type iden‐
Feature
tification
EDS 4
Designation of the pressure
switch
4
Accuracy:
4
Mechanical connection:
8
Electrical connection:
0060
Measuring range:
P
Control output:
A
Certification:
N
Electrical strength:
3
Degrees of protection:
004
Modification number:
F
Sealing material:
1
Connecting material:
200
Cable length:
Variable
Voltage
5–25 V DC, in accordance with Namur or DIN 19234, potential-free
design.
Technical data
Property
EDS 4
Thin film/relative pressure
G ¼ A DIN 3852, external
thread
Device plug, M12x1, 5-pole
specification in bar
programmable
ATEX
125 V AC relative to the
housing
II 2G Ex ia IIC T4
0.5 mm nozzle pressed in
or integrated
including accessories ZBE
08S-02 coupling socket
M12x1, angled with 2 m
wire, screened
FPM
Stainless steel
2 m (standard)
Value
Unit
14 ... 28
V
67

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hp4a

Table of Contents