2.7 Safety information for ATEX designs

2.7.1 Intended use

2.7.2 ATEX qualification of personnel

Task
Planning the hydraulic installation
Electrical installation
Start up
Maintenance, repair
Troubleshooting
12
3.
As you have converted an "incomplete machine" into a complete
machine, you must perform a conformity assessment, risk assess‐
ment, create a Declaration of Conformity, fit a company name‐
plate, ... .
4.
Complete the pump documentation / operating instructions.
Sound pressure level LpA < 70 dB according to EN ISO 20361
at maximum stroke length, maximum stroke rate, maximum back pressure
(water)
This chapter lists all safety information for ATEX designs. Safety informa‐
tion is listed again at the relevant points in these operating instructions.
This safety information is supplementary to or replaces the safety informa‐
tion for non-ATEX designs. If the safety information for ATEX designs con‐
tradicts the other safety information, then the safety information in this
chapter applies to ATEX designs.
Only operate an ATEX design of pump in premises at risk from explo‐
n
sion in accordance with the applicable guidelines.
Pumps with the identity code option "Multi-layer safety diaphragm with
n
rupture signalling (contact)" are only approved for use with flammable
feed chemicals with electrically conductive dosing heads, at back
pressures of over 2 bar and only if the operator takes appropriate
safety measures. Rupture signalling must switch off the pump immedi‐
ately.
Do not expose the ATEX design to any sources of ionising radiation or
n
electromagnetic high frequency radiation in the range 10
or laser radiation or ultrasound or lightning without putting in place
measures in line with EN 80079-38.
Do not allow the ATEX design to meter media, which tends to produce
n
exothermic reactions or self-ignite (examples of exothermic reactions:
pyrophoric substances with air, alkali metal with water, decomposition
of organic peroxides, polymerisation reactions), without taking effec‐
tive measures in accordance with EN 80079-38.
Qualification
ATEX qualified person, ATEX electrical technician
ATEX electrical technician
Skilled ATEX technician;
Checking the electrical installation: Recognised competent person
ATEX qualified person, ATEX electrical technician
Qualified ATEX technician or ATEX electrical technician - depending on
the fault;
Checking the electrical installation: Recognised competent person