Stroke sensor (optional), intrinsically safe

Stroke sensor (optional), intrinsically
safe
Namur sensor (Specified for EX
zones)

13.10 Diaphragm rupture sensor

Motor data sheets, special motors, special motor
flanges, external fan, temperature monitoring
For further information on the motor with iden‐
tity code specification "S", refer to our website
www.prominent.com. Motor data sheets can be
requested for all other motors.
With motors other than those with identity code
specifications "S", "M" or "N": Pay special
attention to the operating instructions for the
motors.
Special motors or special motor flanges are
available on request.
Install the sensor according to the chapter "Instal‐
lation, electrical". Refer to its documentation.
Sensor name: NJ1.5-8GM-N.
5–25 V DC, in accordance with Namur or DIN 19234, potential-free
design.
Data
Rated voltage *
Power consumption - active surface
uncovered
Power consumption - active surface
covered
Rated switching distance
* Ri ~ 1 kΩ
Cable colour
Polarity
blue
-
brown
+
Install the sensor according to the chapter "Instal‐
lation, electrical".
Technical data
Value Unit
8 VDC
> 3 mA
< 1 mA
1.5 mm