Technical data
15.5.2
Media temperatures
Liquid end PVT, PVF
TTT liquid end
Liquid end SST, SSF
15.5.3
Air humidity
Air humidity
15.6
Installation height
15.7
Motor data
Electrical data
Identity code
Phases, protec‐
specification
tion
S
3-phase, IP 55
T
3-phase, IP 55
62
Data
Max. temperature, long-term at max. oper‐
ating pressure
Max. temperature, for 15 minutes at max.
2 bar
Minimum temperature.
Data
Max. temperature, long-term at max. oper‐
ating pressure
Minimum temperature.
Data
Max. temperature, long-term at max. oper‐
ating pressure
Max temperature, for 15 minutes at max. 2
bar
Minimum temperature.
* not in areas at risk from explosion
Air humidity, max. 92 % relative humidity, non-condensing.
Data
Maximum installation height*:
* with standard pumps: Fit at higher installation heights at your own risk.
with ATEX pumps: We urgently advise that you contact a specialist for
ATEX motors at higher installation heights!
Rated voltage
Mains frequency
220-240 V /
50 Hz
380-420 V
265-280 V /
60 Hz
440-480 V
220-240 V /
50 Hz
380-420 V
Value Unit
65 °C
100 °C
-10 °C
Value Unit
50 °C
-10 °C
Value Unit
90 °C
120 °C*
-10 °C
Value Unit
1000 m above
Rated output
Remarks
0.09 kW
0.09 kW
0.09 kW
With PTC, speed
control range 1:5
standard
zero