Motor Data; Stroke Actuator Drive Mechanism; Stroke Adjuster Drive Mechanism; Electrical Data, Stroke Sensor "Sigma - ProMinent S2Ba Operating Instructions Manual

Sigma/ 2 metering pump
Table of Contents

Advertisement

Technical data
Motors:
3 ph IP 55
3 ph IP 55
1 ph AC
1 ph AC
3 ph EXe or EXde
3 ph EXe or EXde
3 ph IP 55
1 ph IP 55
direction
of rotation
Fig. 11
Page 28
3.1.4

Motor data

Electrical Data
230 V/400 V
50 Hz
230 V/400 V
60 Hz
230 V
50/60 Hz
115 V
60 Hz
230 V/400 V
50 Hz
230 V/400 V
60 Hz
230 V/400 V
50/60 Hz
230 V
50/60 Hz
For more details you can request the motor specification sheets. Custom motors and/or custom
motor flanges are available on request.
WARNING
• EX-pump only: Drive motors must be secured by an appropriate motor protection switch.
A motor protection approved for this application must be used for Ex"e"-motors.
(Protection against heating due to overload)
• EX-pump only: motors in EX-areas must be installed and checked by persons with
"recognised skills"!
• EX-pump only: observe the operating manual supplied with the EX motor!
Fuse data
IMPORTANT
• The motors are not fuse-protected. Fit a motor circuit breaker!
• When connecting the motor, make sure that it rotates in the correct direction (see Fig. 11).
Protection against accidental contact and moisture (IP)
Motor: IP 55 DIN EN 60034-5 (in accordance with DIN VDE 0470 Part 1, corresponds to
EN 60529 and IEC 529).
External fan
Notes on the speed-controlled motor with separate fan and temperature monitoring may be
found in the "General Operating Instructions ProMinent
Hydraulic Accessories".
3.1.5

Stroke actuator drive mechanism

230 V ± 10 % 50/60 Hz
115 V ± 10 %
60 Hz
Cf. "Appendix" for terminal connection diagram.
3.1.6

Stroke adjuster drive mechanism

230 V ± 10 % 50/60 Hz
115 V ± 10 %
60 Hz
Cf. "Appendix" for terminal connection diagram.
3.1.7

Electrical data, stroke sensor "Sigma"

a) Reed contact (Identcode characteristic "Stroke sensor": 1)
Pin 1 (white)
=
Pin 2 (brown)
=
Pin 3 (green)
=
Pulse width (low) ≥
0.25 kW
1.62/0.94 A
0.25 kW
1.42/0.82 A
0.18 kW
1.7/1.5 A
0.18 kW
3.3 A
0.18 kW
1.1/0.7 A
0.18 kW
1.1/0.6 A
0.37 kW
......
0.37 kW
.....
11.7 W
11.7 W
6.5 W
6.5 W
4.5 V to 24 V, max. 10 mA
OUT, open collector, 24 V, 20 mA
GND
4 ms (depending on gearbox and power frequency)
Dulcodes UV-Desinfektionsanlage
Identcode characteristic
S
S
M
N
L
P
R Version with external fan
1 PH 230 v; 50/60 Hz and PTC
V Three phase motor with integrated
speed changer, (see chapter 11)
®
Motor-Driven Metering Pumps and
®
ProMinent