en - Technical data

Voltage versions and electrical data

3N AC 400 V SI/SD
Supply voltage
Frequency
Required fuse rating (on site)
Power rating
Connection cable, min. cross-section

Plumbing

Cold water connection

Required flow pressure
Maximum flow rate
Threaded union required (male thread, to be provided by customer in accordance with
DIN 44991, flat sealing)
Length of water inlet hose supplied

Hot water connection

Maximum permissible hot water temperature
Required flow pressure
Maximum flow rate
Threaded union required (male thread, in accordance with DIN 44991, flat sealing)
Length of water inlet hose supplied

Hot water connection (for variants without heating or with reduced heater rating)

Maximum permissible hot water temperature
Required flow pressure
Maximum flow rate
Threaded union required (male thread, in accordance with DIN 44991, flat sealing)
Length of water inlet hose supplied

Hard water connection (optional)

Required flow pressure
Maximum flow rate
Threaded union required (male thread, in accordance with DIN 44991, flat sealing)
Length of water inlet hose supplied

Indirect steam heating

Heater rating (peak capacity)
Threaded union (on site)
Steam solenoid valve, dirt filter and steam shut-off valve must be installed by the customer on site. Follow the installation instructions
for steam-heated machines.

Direct steam heating

Heater rating (peak capacity high pressure)
Threaded union (on site)
Steam solenoid valve, dirt filter and steam shut-off valve must be installed by the customer on site. Follow the installation instructions
for steam-heated machines.
48
3N AC 400 V
50/60 Hz
16 A
3,1 kW
1,5 mm²
100 - 1000 kPa (1 - 10 bar)
31,5 l/min
3 x 3/4"
3 x 1550 mm
70 °C
100 - 1000 kPa (1 - 10 bar)
16 l/min
1 x 3/4"
1550 mm
90 °C
100 - 1000 kPa (1 - 10 bar)
16 l/min
1 x 1"
1550 mm
100 - 1000 kPa (1 - 10 bar)
32 l/min
2 x 3/4"
2 x 1550 mm
27 kW
2 x ½"
37 kW
1 x ½"