C
L
OMMAND
INE
Command Mode
Normal Exec, Privileged Exec
Command Usage
This command displays the current time, the poll interval used for
sending time synchronization requests (when the switch is set to SNTP
client mode), and the current SNTP mode (i.e., client or broadcast).
Example
Console#show sntp
Current time:
Poll interval: 60
Current
SNTP status : Enabled
SNTP server 10.1.0.19 0.0.0.0 0.0.0.0
Current server: 10.1.0.19
Console#

clock timezone

This command sets the time zone for the switch's internal clock.
Syntax
clock timezone name hours hours minute minutes {before-utc |
after-utc}
• name - Name of timezone, usually an acronym.
(Range: 1-29 characters)
• hours - Number of hours before/after UTC. (Range: 0-13 hours)
• minutes - Number of minutes before/after UTC. (Range: 0-59
minutes)
• before-utc - Sets the local time zone before (east) of UTC.
• after-utc - Sets the local time zone after (west) of UTC.
Default Setting
None
Command Mode
Global Configuration
4-74
I
NTERFACE
Jan
1 02:02:27 2005
mode: unicast