Vertical
A/D Converter
VOLTS Range
Position Range
Selectable Analog Bandwidth Limit,
typical
Low Frequency Response (-3db)
Rise Time at BNC, typical
DC Gain Accuracy
DC Measurement Accuracy,
Average Acquisition Mode
Volts Measurement Repeatability,
Average Acquisition Mode
Note: Bandwidth reduced to 6MHz when using a 1X probe.
Trigger
Trigger Sensitivity
(Edge Trigger Type)
DSO1000E Series HandHeld Oscilloscope User Manual
8-bit resolution,
each channel sampled simultaneously
2mV/div to 100V/div at input BNC
±400V(100V/div-20V/div)
±50V(10V/div-5V/div)
±40V(2V/div-500mV/div)
±2V(200mV/div-50mV/div)
±400mV(20mV/div-2mV/div)
20MHz
≤10Hz at BNC
DSO1072E
<5.0ns
± 3% for Normal or Average acquisition mode, 100V/div
to 10mV/div
± 4% for Normal or Average acquisition mode, 5mV/div
to 2mV/div
Measurement Type: Average of ≥16 waveforms with
vertical position at zero
Accuracy: ± (3% × reading + 0.1div + 1mV) when
10mV/div or greater is selected
Measurement Type: Average of ≥16 waveforms with
vertical position not at zero
Accuracy: ± [3% × (reading + vertical position) + 1% of
vertical position + 0.2div]
Add 2mV for settings from 2mV/div to 200mV/div; add
50mV for settings from 200mV/div to 5V/div
Delta volts between any two averages of ≥16
waveforms acquired under same setup and ambient
conditions
Coupling
Sensitivity
Source
DC
CH1
CH2
AC
Attenuates signals below 10Hz
DSO1102E
DSO1152E
<3.5ns
≤2.3ns
DSO1072E
DSO1102E
1div from DC to
10MHz;
1.5div from 10MHz to
Full
Specifications
DSO1202E
<1.8ns
DSO1152E
DSO1202E
1.5div from 10MHz
to 100MHz;
2div from 100MHz
to Full