Hantek DSO1000E Series User Manual page 33

Handheld oscilloscope
Table of Contents

Advertisement

pulse.
Triggers when pulse is
less than width setting
Triggers when pulse is not
equal to width setting ± 5%
=, ≠: Within a ±5% tolerance, triggers the oscilloscope when the signal pulse width is equal to
or not equal to the specified pulse width.
<, >: Triggers the oscilloscope when the source signal pulse width is less than or greater
than the specified pulse width.
Slope Trigger: Judges trigger according to the time for rising or falling, more flexible and accurate
than the Edge trigger.
Options
Slope
Source
Slope
Mode
Coupling
Vertical
When
DSO1000E Series HandHeld Oscilloscope User Manual
Threshold level
Tolerance
= Trigger Point
Settings
CH1
Select the input source as the trigger signal.
CH2
Rising
Select the slope type of signal.
Falling
Auto
Select the type of trigger. The Normal mode is best for
Normal
most pulse width trigger applications.
AC
DC
Selects the components of the trigger signal applied to
Noise Reject
the trigger circuitry.
HF Reject
LF Reject
V1
Adjust the vertical window by setting two trigger levels.
V2
Select this option and press F3 to choose V1 or V2.
=
Select the trigger condition.
<
>
Triggers when pulse is
greater than width setting
Triggers when pulse is
equal to width setting ± 5%
Threshold level
Comments
Basic Operation
Tolerance
28

Advertisement

Table of Contents
loading

Table of Contents