Cooling Agents And Chips Disposal; Coolant Device Inspection; Chips Disposal - Bomar Workline 410.280 DG Operating Instructions Manual

Table of Contents

Advertisement

 
4.7.

Cooling agents and chips disposal

The quality of the cooling
agent will deteriorate due to:
use of contaminated water
impurity
outside oil contamination
(hydraulics, gears)
high operating temperatures
lack of air circulation
wrong concentration
4.7.1.

Coolant device inspection

The state of the cooling agent has significant influence on the cutting quality and on
the operational life of the machine. Lifetime of the cooling liquid is 1 year, after this time
we recommend change the cooling liquid. This time is dependent on the degree of
pollution cooling liquid (especially with oils) and on the other factors.
Check level of the cooling liquid and function of the pump periodically!
Note:
If the state of the cooling liquid is not satisfactory, the cooling
liquid must be changed.
Check the state of the cooling agent according to the following table:
Testing
Interval
Liquid level
daily
Concentration
daily
Smell
daily
Contamination
daily
Corrosion-
when
protection
necessary
when
Stability
necessary
when
Foam reaction
necessary
* According to manufacturers' instructions
4.7.2.

Chips disposal

Chips resulting from cutting operations must be disposed of in accordance with the
relevant regulations.
Let the chips drip excess fluid!.
Fill a watertight container with the chips! Be careful that the container does not
leak, because even after a long dripping time, they still contain coolant residue.
Place the container into the care of a disposal company equipped for the disposal of
chips contaminated with cooling liquid. In case the machine is equipped with micro-
spray installation, the chips must also be handed over to a disposal company.
 
If the solution is too weak:
corrosion protection is
diminished
lubrication decreases
microbial attack is more likely
Method
Condition
visually
too low
too high
refractometer
densimeter
too low
by sense of smell
unpleasant smell
visible oil leaks,
by sense of smell
sludge fungi
visually
insufficient corrosion
chip test
protection
Herbert-test
refractometer
oiling
too much foam, foam
shaking test
disperses too slowly
If the solution is too strong:
the cooling ability is decreased
foam behaviour increases
emulsions stability deteriorates
sticky residue develops
Precaution
after concentration check, refill
with water or emulsion
refill water
refill base emulsion
good ventilation, add biocides
or renew coolant
surface cleaning, fix leaks, add
biocides or fungicides, or
coolant renewal after added
system cleanser*
test stability, if necessary –
increase concentration or pH
value
add concentrate, enquiries to
supplier
avoid aeration, increase water
hardness, ix with defoamer
45