GROUP 6 ELECTRICAL COMPONENT SPECIFICATION
Part name
Battery
Fusible link
Start key
Pressure switch
Pressure switch
Solenoid valve
(Parking, fan
EPPR valve)
Symbol
2
1
CN-60
CN-95
ST C
H
BR ACC
2
3
4
5
6
H
0 I
0, I
B
1 2 3 4 5 6
CS-2
2
Pa
1
CD-3 CD-26
CD-18
A
Pa
B
CD-4
CD-35
CD-75
CD-75
2
1
CN-71 CN-154
CN-71
7-36
Specifications
※ Check specific gravity
× 200Ah
12V
1.280 over
(2EA)
1.280 ~ 1.250 : Normal
1.250 below : Recharging
※ Check disconnection
Normal : 0Ω
CN-60 : 24V 27A
(Connect ring terminal and
CN-95 : 24V 45A
check resistance between
terminal 1 and 2)
※ Check contact
OFF : ∞Ω(For each terminal)
ON : 0Ω(For terminal 1-3)
-
START : 0Ω(For terminal 1-3
※ Check contact
N.C TYPE
Normal : 0Ω(CLOSE)
※ Check contact
N.O TYPE
Normal : ∞Ω(OPEN)
※ Check LED lamp.
※ Check resistance
24V 300A
About 24Ω
Check
: Over charged
∞Ω(For terminal 1-5)
and 1-5)