Technical data
Material load diagram
Process connections
114
Measuring tube(s)
• Promass F
– DN 8 to 100: stainless steel SS 1.4539/904L; manifold: 1.4404/316L
– DN 150: stainless steel 1.4404/316L/1.4432
– DN 250: stainless steel 1.4404/316L/1.4432; manifold: CF3M
– DN 8 to 150: Alloy C-22 2.4602/N 06022
• Promass F (high-pressure version)
– DN 25, 50, 80: Alloy C-22 2.4602/N 06022
• Promass M
– DN 8 to 50: titanium grade 9
– DN 80: titanium grade 2
• Promass M (high pressure version)
– Titanium grade 9
• Promass A
– Stainless steel 1.4539/904L, Alloy C-22 2.4602/N 06022
Seals
• Promass F: Welded process connections without internal seals
• Promass M
– Viton
– EPDM
– Silicone
– Kalrez
– FEP sheathing (not for gas applications)
• Promass A
– Viton
– EPDM
– Silicone
– Kalrez
The material load diagrams (pressure-temperature diagrams) for the process connections are
provided in the separate "Technical Information" document on the measuring instrument in
question. This can be downloaded as a PDF file from www.endress.com.
List of the "Technical Information" documents available → ä 118.
→ ä 113
Proline Promass 84 MODBUS RS485
Endress+Hauser
Need help?
Do you have a question about the Proline Promass 84 MODBUS RS485 and is the answer not in the manual?
Questions and answers