SENSOR GROUPS
WATER
GROUP
38
25
Water Non-Reporting
Please note: When selecting "Water" you will see two additional options under "Sensor Sub-Type". For IQ TempH20 (QS5500-PO1) & the IQ Flood
(QS5516-840/QS5536-840) select "IQ Flood", for all others, select "Other Flood"
SHOCK SENSOR
GROUP
13
Shock-Glass-Break
17
Glass-Break-Away Only
Please note: When selecting "Shock" you will see two additional options under "Sensor Sub-Type". For IQ Shock select "IQ Shock", for all others select
"Other Shock". *Power G Shock Sensor with prefix 170 offers additional sensitivity level functions
*345 MHz water sensors will have the option to change the "Loop" number to 1, 2 or 3. This will
allow the sensor to be programmed twice as 2 different zones where supported by the device
NAME
SUPERVISED
Water Sensor
*345 MHz shock sensors will have the option to change the "Loop" number to 1 or 3. This will
allow the sensor to be programmed twice as 2 different zones where supported by the device
NAME
SUPERVISED
Triggers an alarm when sensor detects presence of water.
Y
NOTE: flood sensor functionality has not been evaluated for UL/cUL, UKCA or CE/EN
Grade 2.
Y
Used for local alerts. Will not report an alarm to the Central Station
Arms and trips shock sensors immediately when armed to both
Y
"Stay" and "Away"
Arms and trips shock sensors immediately when armed only to
Y
"Away"
SCENARIO
SCENARIO