QOLSYS IQ4 Hub Installation Manual page 66

All-in-one 7” (17.8cm) touchscreen
Table of Contents

Advertisement

SENSOR GROUPS
KEY FOB
GROUP
NAME
6
Mobile Auxiliary
Mobile Silent
7
Auxiliary
KEYPAD
GROUP
NAME
0
Fixed Intrusion
1
Mobile Intrusion
2
Fixed Silent
3
Mobile Silent
*345 MHz Keyfobs will follow the IQ Panel' s Keyfob programming and functionality
SUPERVISED
Worn as a wrist watch or pendant, the button(s) is/are programmed to trigger an
N
Auxiliary panic.
Grade 2.
Worn as a wrist watch or pendant, the button(s) is/are programmed to trigger a
N
silent Auxiliary panic.
CE/EN Grade 2.
SUPERVISED
Installed in a fixed location, the keypad is programmed to trigger a police panic.
Y
NOTE: Hold-up functionality has not been evaluated for UL/cUL, UKCA or CE/EN Grade 2.
N
Keypad can be mobile and is programmed to trigger a police panic
Installed in a fixed location, the keypad is programmed to trigger a silent police
Y
panic
N
Keypad can be mobile and is programmed to trigger a silent police panic
SCENARIO
NOTE: Medical functionality has not been evaluated for UL/cUL, UKCA or CE/EN
NOTE: Medical functionality has not been evaluated for UL/cUL, UKCA or
SCENARIO