QOLSYS IQ4 Hub Installation Manual page 135

All-in-one 7” (17.8cm) touchscreen
Table of Contents

Advertisement

SYSTEM TESTS
INPUT VOLTAGE TEST
Input Voltage Test
Measure the voltage received at the Panel in real-time.
Press "Start" to run a real-time voltage test
on the Panel. If voltage received is above
6vDC, you will get a "Voltage is Good"
message.
Note: Test results may vary each time you run the test
based on current draw of the panel at that time.
If voltage is below 6vDC, you will receive a
"Voltage is Low" message and action
should be taken to correct the low voltage
condition (i.e. use thicker gauge wire or
shorten the wire run).
Note: Wire run length and gauge should not exceed
UL specification.
QOLSYS CONFIDENTIAL AND PROPRIETARY
PAGE
135
OF
197
FIND IT
Swipe down
for access
SETTINGS
ADVANCED SETTINGS
ENTER CODE (1111, 2222)
SYSTEM TESTS
INPUT VOLTAGE TEST

Advertisement

Table of Contents
loading