PROGRAMMING
INSTALLER/DEALER SETTINGS
Setting
Loss of Supervisory Signals for Z-
Wave
Loss of Supervisory Signals for Non
Emergency Sensors
Loss of Supervisory Signals for
PowerG Non Emergency Sensors
Loss of Cell Signal Timeout
Communication Test
Communication Test Start Time
Default
4
Select the length in hours (4, 24) before reporting a loss of supervision on Z-Wave Sirens.
Select the length in hours (4, 12, 24) before reporting a loss of supervision on security
devices.
24
NOTE: For UL/cUL Resi Fire and UL Commercial Burg (UL2610) the wireless supervision window for Non-Emergency
sensors (all intrusion sensors) shall be set to 4h. These devices shall not be used for EN Grade 2 compliant installations
Select the length of time (20, 30 min, 1, 2, 4, 12, 24 hours) before reporting a loss of
supervision on PowerG security devices.
24
NOTE: For UL/cUL Resi Fire and UL Commercial Burg (UL2610) the wireless supervision window for Non-Emergency
sensors (all intrusion sensors) shall be set to 4h. For EN Grade 2, the supervision window shall be set for 20 minutes.
Select the length in minutes (10-120) before reporting a loss in cellular signal.
30
NOTE: For UL Commercial Burg (UL2610) the cell supervision is hardcoded to 200s
Choose Never, Daily, Weekly or Monthly when enabling the communication test.
Monthly
NOTE: For UL Resi Fire (UL985) the test frequency shall be set to Weekly. By default the system will be set to Weekly if
UL985 is selected on Alarm.com
Select the time of day that the panel will send its Communication Test. If no time is
Randomized
selected the time will automatically be randomized.
QOLSYS CONFIDENTIAL AND PROPRIETARY
PAGE
29