QOLSYS IQ4 Hub Installation Manual page 119

All-in-one 7” (17.8cm) touchscreen
Table of Contents

Advertisement

SYSTEM TESTS
SENSOR TEST
Colored points on the graph represent each state change or supervisory signal
transmitted from a sensor to the panel. Points are colored based on frequency.
The
YELLOW
line represents a dBm level where signal strength is "Poor" and potential
RF failures could occur. This line dynamically adjusts to 12 dBm above the ambient RF
noise floor in the environment.
The
RED
line represents a dBm level where signal strength is "Critical" and RF failures
are likely. This line dynamically adjusts to 6 dBm above the ambient RF noise floor in
the environment.
TROUBLESHOOTING:
If a sensor falls below the yellow
line, try changing it' s orientation
(vertical/horizontal), move the
sensor to a different part of the
door/window or adjust the panel
location.
Then re-test to see the if the result
improved.
QOLSYS CONFIDENTIAL AND PROPRIETARY
PAGE
119
OF
197
FIND IT
Swipe down
for access
SETTINGS
ADVANCED SETTINGS
ENTER CODE (1111, 2222)
SYSTEM TESTS
SENSOR TEST
NOTE: Manufacturer recommended
signal to noise ratio is min 10dB